Skip to main content
Loading…
This section is included in your selections.

Section 115 of the CFC, Pipeline setbacks, is added to read as follows:

115 Pipeline setbacks.

115.1 Pipeline setbacks. For purposes of this section “high pressure transmission line” is a natural gas pipeline operating at two hundred and fifty pounds per square inch or greater. A gas main or transmission line is a natural gas pipeline operating at sixty pounds per square inch or less.

115.2 No portion of a structure including accessory buildings and pools may be built within fifty feet of a high pressure transmission line with thirty-six inches of cover.

115.3 No structure may be built within forty feet of a hazardous liquid pipeline bearing refined product, with forty-eight inches or more of cover.

115.4 No habitable portion of a structure may be built within thirty feet of a crude oil pipeline operating at twenty percent or greater of its design strength.

(Ord. 5119 § 1, 2023; Ord. 4997 § 1, 2019; Ord. 4877 § 1, 2016; Ord. 4739 § 1, 2013; Ord. 4636 § 1, 2010; Ord. 4474 § 1, 2007)