15.05.160 Section 2304 amended—General construction requirements.
Subsection 2304.12.2.8 is amended to read as follows:
2304.12.2.8 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 (Commodity Specifications A or F) for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F.
Subsection 2308.6.8.1 is amended to read as follows:
2308.6.8.1 Braced wall line support. Braced wall lines shall be supported by continuous foundations.
Exception: For structures with a maximum plan dimension not over 50 feet (15240 mm), continuous foundations are required at exterior walls only for structures not assigned to Seismic Design Category D, E or F.
(Ord. 5111 § 2, 2022; Ord. 4994 § 3, 2019; Ord. 4878 § 3, 2016; Ord. 4755 § 3, 2013; Ord. 4637 § 3, 2010)